Metal Finishing - SCR
The Space Saver SCR
A Small Solution
To A Big Problem..
The Space Saver SCR
Rapid's Smaller Footprint Design
Solves Your Space Problem
Rapid Power's smaller footprint rack-mountable "Space Saver" SCR Thyristor offers all the same ultra-reliable power rectification features you’ve come to expect of our standard SCR's, including sealed electronics! Rapid’s thermo-mechanical design allows all control circuitry and wiring to be safely sealed away from the corrosive plating atmosphere which is the major reason for rectifier failures. Housed in an industrial grade epoxy-coated enclosure with a heavy gauge stainless steel front panel, this powerhouse is built to last.
Unit Specifications
Single Phase:
| Input Voltage: | 100 to 125, VAC 60Hz, single-phase.
(or) 190 to 250 VAC 60 Hz, single-phase.
|
| Output Voltage & Current: | 0 - 50A., 6, 12, 18, 24 VDC
0 - 100 A., 6, 12, 18, VDC
0 - 150 A., 6 VDC
0 - 200 A., 6 VDC
|
| Dimensions: | 5.25" H x 19" W x 20" D |
| Output Voltage & Current: | 0 - 100 A., 24 VDC
0 - 150 A., 12, 18, 24 VDC
0 - 200 A., 12, 18 VDC |
| Dimensions: | 7" H x 19" W x 20" D |
| Output Voltage & Current: | 0 – 200 A., 24 VDC
0 - 300 A., 6 V, 12 VDC |
| Dimensions: | 8.75" H x 19" W x 20" D |
Three Phase:
| Input Voltage: | 190 to 250, VAC 60 Hz, three-phase (or) 390 to 510 VAC 60 Hz, three-phase |
| Output Voltage & Current: |
0 - 300 A., 18, 24 VDC
0 - 500 A., 6, 12 VDC |
| Dimensions: | 12.25" H x 19" W x 27" D |
| Output Voltage & Current: |
0 - 500 A., 18, 24 VDC
0 - 750 A., 6, 12 VDC
0 - 1000 A., 6, 12 VDC |
| Dimensions: | 21" H x 19" W x 27" D |
(Specifications subject to change without notice)
Conventional SCR (figure 1) The 200 Amp, 6 Volt SCR on the left takes up 3.3 square feet. Ten of them would take up 33 square feet of valuable floor space.
Space Saver (figure 2)
On the right, ten new Space Saver 200 Amp 6 Volt SCR's, rack-mounted-(yes, you can fit ten of them in one rack!) taking up only 4.35 square feet of floor space! That's a savings of 28.7 square feet! When you need to save floor space (and who doesn't), Rapid comes to the rescue-with the Space Saver SCR!
ADDITIONAL FEATURES INCLUDE:
- Available rack or bench mounting configurations
Ripple: 1% of setpoint (standard)
Regulation ±0.5%
Low Audible Noise
Digital Meters
Current Limiting
Voltage Limiting
Automatic Voltage Stabilization
Thermal Detectors
Automatic Constant Current
Automatic Crossover
Peak Overload Detection
AC Circuit Breaker with Shunt Trip (1 phase)
AC Contactor with start/stop (3 phase)
Operating Temp., 0° C to 50° C (32° F to 122° F)
Available Options Include:
- Remote Control
- Variable Ramp
- Computer Interface
- 50Hz
- Automatic Current Density
|